We performed a radiofrequency catheter ablation of atrial fibrillation by means of high-density electroanatomical mapping of the left atrium. During radiofrequency delivery into the Right Superior Pulmonary Vein (RSPV), we observed restoring of sinus rhythm. Post-ablation re-mapping of the left atrium in sinus rhythm evidenced isolated fibrillatory activity confined to the RSPV. Such finding is not common and confirms that a complete electrical isolation of this vein was obtained during the procedure.
Keywords: Atrial fibrillation; Catheter ablation; Pulmonary veins
A 67-year-old man (W 72 kg, H 175 cm, CHA2 DS2 -VASc = 1 due to hypertensive state) was admitted to our EP lab complaining brief and repetitive episodes of atrial fibrillation. He had previously undergone radiofrequency catheter ablation of the cavo-tricuspid isthmus because of the occurrence of common atrial flutter episodes.
High-density electrophysiological mapping of the left atrium was obtained by means of CARTO 3 software (Biosense-Webster) Confidense tool and multipolar Pentaray catheter, aiming to identify low potentials belonging to veno-atrial electrical connection areas (Figure1).
During the procedure, atrial fibrillation was accidentally induced. Radiofrequency delivery at the ostium of the Right Superior Pulmonary Vein (RSPV) was followed by restoring of persistent sinus rhythm (Figure 2).
Post-ablation high-density mapping documented the persistence of fibrillation potentials in the RSPV, despite the presence of sinus rhythm (Figure 3). Thus, a complete disconnection of this vein was confirmed. The great importance of the RSPV for the genesis and maintenance of atrial fibrillation in this patient was demonstrated as well.
Two years later the patient was found asymptomatic and in good clinical condition.
Figure 1: High-density electroanatomical CARTO mapping of the left atrium by means of Confidense tool and multipolar Pentaray catheter. Fragmented areas of low potentials are visible at the level of the pulmonary antra. Panel A: Antero-posterior view. Panel B: Postero-anterior view. LAA: Left Atrial Appendage; LSPV: Left Superior Pulmonary Vein; LIPV: Left Inferior Pulmonary Vein; RSPV: Right Superior Pulmonary Vein; RIPV: Right Inferior Pulmonary Vein.
Figure 2: During ablation in the right superior pulmonary vein, atrial fibrillation was interrupted and persistent sinus rhythm was achieved. This phenomenon is visible at the level of the coronary sinus signals (green potentials, red arrow). The position of the Navistar ablation catheter in the RSPV is evidenced by a red arrow as well. LAA: Left Atrial Appendage; LSPV: Left Superior Pulmonary Vein; LIPV: Left Inferior Pulmonary Vein; RSPV: Right Superior Pulmonary Vein; RIPV: Right Inferior Pulmonary Vein; CS: Coronary Sinus
Figure 3: Post-ablation mapping of the right superior pulmonary vein with the multipolar Pentaray catheter (white potentials, red arrow) shows the persistence of fibrillation potentials inside the vein together with the presence of sinus rhythm at the level of the coronary sinus leads (green potentials). LSPV: Left Superior Pulmonary Vein; LIPV: Left Inferior Pulmonary Vein; RSPV: Right Superior Pulmonary Vein; RIPV: Right Inferior Pulmonary Vein; CS: Coronary Sinus.
Since the main goal of atrial fibrillation ablation consists of achieving a complete electrical disconnection of the pulmonary veins [1-4], the observation of an isolated fibrillatory activity in the RSPV, which was not spread to the rest of the left atrium, confirmed the efficacy of the procedure and was associated to a favorable outcome. To the best of our knowledge no previous image concerning this topic has been published so far.